{"product_id":"dyness-stack100-bdu-base-battery-management-system","title":"Dyness | Stack100 BDU \u0026 Base | Battery Management System","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003eDyness Stack100 BDU \u0026amp; Base Communication Module\u003c\/h2\u003e\n\u003cp\u003e2: \u003cmeta charset=\"UTF-8\"\u003eDY-STACK100-BDU-BASE\u003cspan\u003e \u003c\/span\u003eStorage Systems - Communication Module\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"18\" width=\"18\" alt=\"Pdf free icon\" src=\"https:\/\/cdn-icons-png.flaticon.com\/512\/136\/136522.png\" style=\"font-size: 14.000001px; margin-bottom: 0px;\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/3103\/9284\/files\/Dyness_CI_EnergySolutions_Brochure.pdf?v=1758119058\" title=\"Dyness C\u0026amp;I Brochure\" rel=\"noopener\" target=\"_blank\"\u003eDyness C\u0026amp;I Product Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"18\" width=\"18\" alt=\"Pdf free icon\" src=\"https:\/\/cdn-icons-png.flaticon.com\/512\/136\/136522.png\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/3103\/9284\/files\/Dyness_Stack_100_Datasheet.pdf?v=1758119142\" title=\"Dyness Stack 100 Datasheet\" rel=\"noopener\" target=\"_blank\"\u003eDyness Stack100 Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"18\" width=\"18\" alt=\"Pdf free icon\" src=\"https:\/\/cdn-icons-png.flaticon.com\/512\/136\/136522.png\" style=\"font-size: 14.000001px; margin-bottom: 0px;\"\u003e \u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/3103\/9284\/files\/Dyness_Product_Compatiblity.pdf?v=1758119020\" title=\"Dyness Product Compatibility List\" target=\"_blank\"\u003eDyness Product Compatibility\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cimg height=\"18\" width=\"18\" alt=\"Pdf free icon\" src=\"https:\/\/cdn-icons-png.flaticon.com\/512\/136\/136522.png\" style=\"font-size: 14.000001px; margin-bottom: 0px;\"\u003e \u003ca rel=\"noopener\" title=\"Dyness Stack 100 User Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/3103\/9284\/files\/Dyness_STACK100_User_Manual-EN-0826.pdf?v=1758119010\" target=\"_blank\"\u003eDyness Stack 100 User Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cspan style=\"color: #121111;\"\u003eTo view complete Dyness full range please visit our \u003ca rel=\"noopener\" href=\"https:\/\/www.itstechnologies.shop\/collections\/dyness-battery-storage\" title=\"Dyness bracket\" target=\"_blank\"\u003eDyness main page\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"300\" data-end=\"629\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eDyness Stack100 Battery Management BDU \u0026amp; Base UK\u003c\/h3\u003e\n\u003cp data-start=\"300\" data-end=\"629\"\u003eThe Dyness Stack100 Battery Management BDU \u0026amp; Base is the central control hub for the Stack100 battery system. Critical for safe, efficient operation, this Communication Module delivers intelligent protection, thermal management, and real‑time connectivity—ideal for home, business, or large‑scale energy storage applications.\u003c\/p\u003e\n\u003chr data-start=\"631\" data-end=\"634\"\u003e\n\u003ch4 data-start=\"636\" data-end=\"663\"\u003eKey Features \u0026amp; Benefits\u003c\/h4\u003e\n\u003ch4 data-start=\"665\" data-end=\"703\"\u003eIntelligent Protection \u0026amp; Safety\u003c\/h4\u003e\n\u003cul data-start=\"704\" data-end=\"949\"\u003e\n\u003cli data-start=\"704\" data-end=\"812\"\u003e\n\u003cp data-start=\"706\" data-end=\"812\"\u003eComprehensive fault detection and protection (over‑voltage, under‑voltage, over‑current, short circuit).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"813\" data-end=\"949\"\u003e\n\u003cp data-start=\"815\" data-end=\"949\"\u003eThermal management ensures reliable function across a wide temperature range, safeguarding both the BDU and connected battery modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"951\" data-end=\"987\"\u003eScalable System Compatibility\u003c\/h4\u003e\n\u003cul data-start=\"988\" data-end=\"1259\"\u003e\n\u003cli data-start=\"988\" data-end=\"1054\"\u003e\n\u003cp data-start=\"990\" data-end=\"1054\"\u003eSupports up to \u003cstrong data-start=\"1005\" data-end=\"1029\"\u003e15 modules per tower\u003c\/strong\u003e for modular expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1055\" data-end=\"1149\"\u003e\n\u003cp data-start=\"1057\" data-end=\"1149\"\u003eAllows up to \u003cstrong data-start=\"1070\" data-end=\"1095\"\u003e12 towers in parallel\u003c\/strong\u003e, delivering aggregate capacity of \u003cstrong data-start=\"1130\" data-end=\"1146\"\u003eover 920 kWh\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1150\" data-end=\"1259\"\u003e\n\u003cp data-start=\"1152\" data-end=\"1259\"\u003eOne BDU (plus base) required per tower — enables large‑scale systems without sacrificing per‑tower control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1261\" data-end=\"1295\"\u003eRemote Monitoring \u0026amp; Updates\u003c\/h4\u003e\n\u003cul data-start=\"1296\" data-end=\"1483\"\u003e\n\u003cli data-start=\"1296\" data-end=\"1360\"\u003e\n\u003cp data-start=\"1298\" data-end=\"1360\"\u003eBuilt‑in \u003cstrong data-start=\"1307\" data-end=\"1328\"\u003eWiFi connectivity\u003c\/strong\u003e for remote system monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1361\" data-end=\"1483\"\u003e\n\u003cp data-start=\"1363\" data-end=\"1483\"\u003eSupports \u003cstrong data-start=\"1372\" data-end=\"1411\"\u003eOTA (Over‑The‑Air) firmware updates\u003c\/strong\u003e—ensuring the system remains up to date without needing physical access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1485\" data-end=\"1488\"\u003e\n\u003ch4 data-start=\"1490\" data-end=\"1518\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable style=\"width: 100.089%;\" data-start=\"1520\" data-end=\"2116\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1520\" data-end=\"1546\"\u003e\n\u003ctr data-start=\"1520\" data-end=\"1546\"\u003e\n\u003cth style=\"width: 29.9822%;\" data-start=\"1520\" data-end=\"1536\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"width: 69.6581%;\" data-start=\"1536\" data-end=\"1546\" data-col-size=\"md\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1575\" data-end=\"2116\"\u003e\n\u003ctr data-start=\"1575\" data-end=\"1625\"\u003e\n\u003ctd style=\"width: 29.9822%;\" data-start=\"1575\" data-end=\"1601\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1577\" data-end=\"1600\"\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.6581%;\" data-start=\"1601\" data-end=\"1625\" data-col-size=\"md\"\u003eDY‑STACK100‑BDU‑BASE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1626\" data-end=\"1704\"\u003e\n\u003ctd style=\"width: 29.9822%;\" data-start=\"1626\" data-end=\"1641\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1628\" data-end=\"1640\"\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.6581%;\" data-start=\"1641\" data-end=\"1704\" data-col-size=\"md\"\u003eCommunication Module \/ Battery Management Unit (BDU \u0026amp; Base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1705\" data-end=\"1741\"\u003e\n\u003ctd style=\"width: 29.9822%;\" data-start=\"1705\" data-end=\"1729\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1707\" data-end=\"1728\"\u003eModules per Tower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.6581%;\" data-start=\"1729\" data-end=\"1741\" data-col-size=\"md\"\u003eUp to 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1742\" data-end=\"1779\"\u003e\n\u003ctd style=\"width: 29.9822%;\" data-start=\"1742\" data-end=\"1767\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1744\" data-end=\"1766\"\u003eTowers in Parallel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.6581%;\" data-start=\"1767\" data-end=\"1779\" data-col-size=\"md\"\u003eUp to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1780\" data-end=\"1849\"\u003e\n\u003ctd style=\"width: 29.9822%;\" data-start=\"1780\" data-end=\"1807\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1782\" data-end=\"1806\"\u003eMax Storage Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.6581%;\" data-start=\"1807\" data-end=\"1849\" data-col-size=\"md\"\u003eOver 920 kWh (with full configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1850\" data-end=\"1915\"\u003e\n\u003ctd style=\"width: 29.9822%;\" data-start=\"1850\" data-end=\"1875\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1852\" data-end=\"1874\"\u003eThermal Management\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.6581%;\" data-start=\"1875\" data-end=\"1915\" data-col-size=\"md\"\u003eIntegrated cooling \/ safety features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1916\" data-end=\"1978\"\u003e\n\u003ctd style=\"width: 29.9822%;\" data-start=\"1916\" data-end=\"1935\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1934\"\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.6581%;\" data-start=\"1935\" data-end=\"1978\" data-col-size=\"md\"\u003eWiFi for remote monitoring, OTA updates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1979\" data-end=\"2009\"\u003e\n\u003ctd style=\"width: 29.9822%;\" data-start=\"1979\" data-end=\"1992\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1981\" data-end=\"1991\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.6581%;\" data-start=\"1992\" data-end=\"2009\" data-col-size=\"md\"\u003eApprox. 13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2010\" data-end=\"2116\"\u003e\n\u003ctd style=\"width: 29.9822%;\" data-start=\"2010\" data-end=\"2036\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2012\" data-end=\"2035\"\u003eSafety \u0026amp; Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.6581%;\" data-start=\"2036\" data-end=\"2116\" data-col-size=\"md\"\u003eOver‑voltage, under‑voltage, over‑current, short circuit, thermal protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2118\" data-end=\"2121\"\u003e\n\u003ch4 data-start=\"2123\" data-end=\"2169\"\u003eWhy Choose the Dyness Stack100 BDU \u0026amp; Base?\u003c\/h4\u003e\n\u003cul data-start=\"2171\" data-end=\"2695\"\u003e\n\u003cli data-start=\"2171\" data-end=\"2304\"\u003e\n\u003cp data-start=\"2173\" data-end=\"2304\"\u003e\u003cstrong data-start=\"2173\" data-end=\"2193\"\u003eHigh Scalability\u003c\/strong\u003e: Expand from small setups to multi‑tower installations while still maintaining per‑tower control and safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2305\" data-end=\"2423\"\u003e\n\u003cp data-start=\"2307\" data-end=\"2423\"\u003e\u003cstrong data-start=\"2307\" data-end=\"2331\"\u003eReliability \u0026amp; Safety\u003c\/strong\u003e: Advanced protection systems and thermal control reduce risk and prolong system lifespan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2424\" data-end=\"2527\"\u003e\n\u003cp data-start=\"2426\" data-end=\"2527\"\u003e\u003cstrong data-start=\"2426\" data-end=\"2449\"\u003eEase of Maintenance\u003c\/strong\u003e: Remote monitoring and OTA updates save time and reduce onsite involvement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2528\" data-end=\"2695\"\u003e\n\u003cp data-start=\"2530\" data-end=\"2695\"\u003e\u003cstrong data-start=\"2530\" data-end=\"2563\"\u003eStrong ROI for Energy Storage\u003c\/strong\u003e: Ideal for UK renewable energy setups—home battery backup, solar storage, commercial systems—providing flexibility as demand grows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2697\" data-end=\"2700\"\u003e\n\u003ch4 data-start=\"2702\" data-end=\"2739\"\u003eInstallation Notes \u0026amp; Requirements\u003c\/h4\u003e\n\u003cul data-start=\"2741\" data-end=\"3034\"\u003e\n\u003cli data-start=\"2741\" data-end=\"2815\"\u003e\n\u003cp data-start=\"2743\" data-end=\"2815\"\u003eOne BDU \u0026amp; Base \u003cstrong data-start=\"2758\" data-end=\"2789\"\u003emust be installed per tower\u003c\/strong\u003e in the Stack100 system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2816\" data-end=\"2906\"\u003e\n\u003cp data-start=\"2818\" data-end=\"2906\"\u003eEnsure adequate cooling and ventilation around the unit to support thermal management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2907\" data-end=\"3034\"\u003e\n\u003cp data-start=\"2909\" data-end=\"3034\"\u003eStable WiFi network required for remote monitoring and OTA updates—recommend a secure connection with sufficient bandwidth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/3103\/9284\/files\/Dyness_Stack_100_Datasheet_Pg_1.png?v=1758120018\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Dyness","offers":[{"title":"Default Title","offer_id":56941930414461,"sku":"DY-STACK100-BDU-BASE","price":809.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0257\/3103\/9284\/files\/dyness_base_bmu.png?v=1763991133","url":"https:\/\/www.itstechnologies.uk\/products\/dyness-stack100-bdu-base-battery-management-system","provider":"ITS Technologies","version":"1.0","type":"link"}