{"product_id":"eastron-sdm630mct-etl-for-sunsynk-digital-meter-kit-three-phase","title":"Eastron | SDM630MCT-ETL | For Sunsynk Digital Meter Kit | Three-Phase","description":"\u003cdl\u003e\n\u003cdt\u003e\n\u003ch2\u003eSunsynk - Eastron - Digital Meter Kit - Three-Phase\u003c\/h2\u003e\n\u003c\/dt\u003e\n\u003cdt\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdt\u003e\u003c\/dt\u003e\n\u003cdt\u003e\u003c\/dt\u003e\n\u003cdt\u003e\u003c\/dt\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e#3: SUN-METER-E-3P \u003cbr\u003e#20: E-METER3-SUNSYNK | Storage Systems | Storage Energy Meter\u003c\/span\u003e\u003c\/dt\u003e\n\u003c\/dl\u003e\n\u003cp data-start=\"83\" data-end=\"147\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cimg height=\"18\" width=\"18\" alt=\"Pdf free icon\" src=\"https:\/\/cdn-icons-png.flaticon.com\/512\/136\/136522.png\" style=\"font-size: 14.000001px; margin-bottom: 0px;\"\u003e\u003ca rel=\"noopener\" title=\"eastron digital meter for sunsynk user manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/3103\/9284\/files\/Eastrons_dm630mct_user_manual_2019v1.1.pdf?v=1759043497\" target=\"_blank\"\u003e Eastron Digital Meter User Manual User Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"83\" data-end=\"147\"\u003eEastron Three Phase \u003cmeta charset=\"utf-8\"\u003eMeter Kit (V1, includes V2 Manual)\u003c\/h3\u003e\n\u003cp data-end=\"828\" data-start=\"487\"\u003eThe \u003cstrong data-end=\"526\" data-start=\"491\"\u003eEastron SDM630MCT‑ETL Meter Kit\u003c\/strong\u003e is a high‑precision energy meter designed for reliable, real-time monitoring of electrical consumption. Paired with CT clamps, it enables detailed measurement of three-phase or single-phase systems. Ideal for solar PV installations, battery systems, micro‑grids, and advanced energy management setups.\u003c\/p\u003e\n\u003cp data-end=\"963\" data-start=\"830\"\u003eThis meter kit is tailored for the UK, compliant with ETL standards, and includes essential accessories to get you started.\u003c\/p\u003e\n\u003ch4 data-start=\"970\" data-end=\"993\"\u003eWhat’s in the Box\u003c\/h4\u003e\n\u003cul data-start=\"995\" data-end=\"1101\"\u003e\n\u003cli data-start=\"995\" data-end=\"1062\"\u003e\n\u003cp data-start=\"997\" data-end=\"1062\"\u003e\u003cstrong data-start=\"997\" data-end=\"1062\"\u003e1 × Eastron SDM630MCT‑ETL Meter \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1063\" data-end=\"1101\"\u003e\n\u003cp data-start=\"1065\" data-end=\"1101\"\u003e\u003cstrong data-start=\"1065\" data-end=\"1101\"\u003e4 × CT clamps, rated 150 A \/ 1 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1063\" data-end=\"1101\"\u003e\n\u003cp data-start=\"1065\" data-end=\"1101\"\u003e\u003cstrong data-start=\"1065\" data-end=\"1101\"\u003e\u003c\/strong\u003e\u003cstrong data-start=\"1108\" data-end=\"1152\"\u003eNote for Sunsynk 3‑Phase Inverter Users:\u003c\/strong\u003e\u003cbr data-start=\"1152\" data-end=\"1155\"\u003eThe Sunsynk 3‑phase inverters include \u003cstrong data-start=\"1195\" data-end=\"1232\"\u003e4 × CT clamps rated 100 A \/ 50 mA\u003c\/strong\u003e (not 150 A \/1 A). Please check compatibility before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"963\" data-start=\"830\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong data-end=\"3359\" data-start=\"3318\"\u003eTo Ensure CT clamp rating compatibility:\u003c\/strong\u003e The included 150 A \/ 1 A clamps suit most domestic and commercial setups, but some inverters (e.g. Sunsynk 3‑phase) expect \u003cstrong data-end=\"3507\" data-start=\"3483\"\u003e100 A \/ 50 mA clamps\u003c\/strong\u003e — double-check before installation.\u003c\/p\u003e\n\u003chr data-start=\"445\" data-end=\"448\"\u003e\n\u003ch4 data-start=\"450\" data-end=\"467\"\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1337\" data-end=\"1390\"\u003e\n\u003cp data-start=\"1339\" data-end=\"1390\"\u003eHigh‑accuracy CT metering for precise measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1391\" data-end=\"1447\"\u003e\n\u003cp data-start=\"1393\" data-end=\"1447\"\u003eSupport for three-phase or split-phase installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1448\" data-end=\"1498\"\u003e\n\u003cp data-start=\"1450\" data-end=\"1498\"\u003eETL certified (ensuring safety and compliance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1499\" data-end=\"1566\"\u003e\n\u003cp data-start=\"1501\" data-end=\"1566\"\u003eSupplied manual in V2 version – easier to follow, more features\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1567\" data-end=\"1619\"\u003e\n\u003cp data-start=\"1569\" data-end=\"1619\"\u003eDownloadable original V1 manual for archival use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1620\" data-end=\"1669\"\u003e\n\u003cp data-start=\"1622\" data-end=\"1669\"\u003eRobust construction for long-term reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1670\" data-end=\"1738\"\u003e\n\u003cp data-start=\"1672\" data-end=\"1738\"\u003eCompatible with energy systems, inverters, and smart controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable data-start=\"1777\" data-end=\"2637\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1777\" data-end=\"1853\"\u003e\n\u003ctr data-start=\"1777\" data-end=\"1853\"\u003e\n\u003cth data-start=\"1777\" data-end=\"1811\" data-col-size=\"sm\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1811\" data-end=\"1853\" data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1930\" data-end=\"2637\"\u003e\n\u003ctr data-start=\"1930\" data-end=\"2005\"\u003e\n\u003ctd data-start=\"1930\" data-end=\"1963\" data-col-size=\"sm\"\u003eMeter Model\u003c\/td\u003e\n\u003ctd data-start=\"1963\" data-end=\"2005\" data-col-size=\"md\"\u003eEastron SDM630MCT‑ETL (V1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2006\" data-end=\"2082\"\u003e\n\u003ctd data-start=\"2006\" data-end=\"2040\" data-col-size=\"sm\"\u003eCT Clamps Supplied\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2040\" data-end=\"2082\"\u003e4 × 150 A : 1 A clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2083\" data-end=\"2160\"\u003e\n\u003ctd data-start=\"2083\" data-end=\"2117\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"2117\" data-end=\"2160\" data-col-size=\"md\"\u003eTypically ±0.5% (check manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2161\" data-end=\"2237\"\u003e\n\u003ctd data-start=\"2161\" data-end=\"2195\" data-col-size=\"sm\"\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd data-start=\"2195\" data-end=\"2237\" data-col-size=\"md\"\u003eAC current, voltage, power, energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2238\" data-end=\"2315\"\u003e\n\u003ctd data-start=\"2238\" data-end=\"2272\" data-col-size=\"sm\"\u003eSupported System\u003c\/td\u003e\n\u003ctd data-start=\"2272\" data-end=\"2315\" data-col-size=\"md\"\u003e1‑phase, 3‑phase, split phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2316\" data-end=\"2402\"\u003e\n\u003ctd data-start=\"2316\" data-end=\"2351\" data-col-size=\"sm\"\u003eCommunication Interface (if any)\u003c\/td\u003e\n\u003ctd data-start=\"2351\" data-end=\"2402\" data-col-size=\"md\"\u003e(State if modbus\/RS485 or pulse, as applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2403\" data-end=\"2482\"\u003e\n\u003ctd data-start=\"2403\" data-end=\"2437\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2437\" data-end=\"2482\" data-col-size=\"md\"\u003e(Specify if known, e.g. –10 °C to +60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2483\" data-end=\"2559\"\u003e\n\u003ctd data-start=\"2483\" data-end=\"2517\" data-col-size=\"sm\"\u003eEnclosure \/ IP Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2517\" data-end=\"2559\"\u003e(If applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2560\" data-end=\"2637\"\u003e\n\u003ctd data-start=\"2560\" data-end=\"2595\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2595\" data-end=\"2637\" data-col-size=\"md\"\u003e(Voltage range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-end=\"4452\" data-start=\"4295\"\u003e\u003cstrong\u003eWhy Choose the Eastron Three Phase \u003cmeta charset=\"utf-8\"\u003eMeter Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"4452\" data-start=\"4295\"\u003eBy combining high precision, UK warranty compliance, and full documentation support, this meter kit is an excellent addition to your energy monitoring setup.\u003c\/p\u003e\n\u003cp data-end=\"4452\" data-start=\"4295\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"3262\" data-start=\"3137\"\u003e\u003cmeta charset=\"utf-8\"\u003eSunsynk products are automatically covered under warranty.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sunsynk-exclude","offers":[{"title":"Default Title","offer_id":57035598201213,"sku":"SUN-METER-E-3P","price":171.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0257\/3103\/9284\/files\/Eastron_SDM630MCT_for_Solis.png?v=1769693641","url":"https:\/\/www.itstechnologies.uk\/products\/eastron-sdm630mct-etl-for-sunsynk-digital-meter-kit-three-phase","provider":"ITS Technologies","version":"1.0","type":"link"}